Electromagnetic vs. Piezoelectric Transducers in Bone Anchored Hearing Systems

Electromagnetic vs. Piezoelectric Transducers in Bone Anchored Hearing Systems

Surgically gloved hand holding hearing processor

What Audiologists Need to Know

Key Takeaways:

  1. Electromagnetic transducers, like those in the Sentio™ System, provide smoother and more natural sound compared to piezoelectric transducers, which can experience distortion at higher frequencies.6
  2. Patients using the Sentio System experience fewer battery interruptions, with up to 60 hours of battery life, including streaming.7
  3. Clinical trials show 94% of patients found Sentio’s sound quality natural or very natural, with 97% reporting improved quality of life.7

Bone anchored hearing systems (BAHS) provide life-changing hearing solutions for patients with conductive hearing loss, mixed hearing loss, or single-sided deafness. Central to these systems is the transducer, which converts electrical signals into mechanical vibrations that stimulate the skull and cochlea. While both piezoelectric and electromagnetic transducers achieve this goal, the differences in their mechanisms lead to significant variations in sound quality, efficiency, and overall patient experience.

This article explores how these two technologies function and why the Sentio System’s electromagnetic transducer offers distinct advantages in delivering high-quality, reliable hearing solutions.

How Transducers Work

Transducers in BAHS work as bone oscillators that transform electrical signals from the sound processor into vibrations, which are transmitted to the inner ear.1 While both piezoelectric and electromagnetic technologies serve this purpose, they differ in their fundamental design:

  • Electromagnetic Transducers (used in the Sentio System): Operate with an electromagnetic circuit comprised of coils, permanent magnets, and magnetically conductive materials. Electrical signals passing through the circuit produce vibrations that are transferred to the skull.2
  • Piezoelectric Transducers: Uses piezoelectric crystals that deform in response to electrical signals from the external sound processor. This deformation generates the mechanical vibrations needed for sound transmission.3

The Advantages of Sentio’s Electromagnetic Transducer

Enhanced Sound Quality

Electromagnetic transducers, like the one in the Sentio System, provide an even frequency response resulting in a richer, more natural sound.2 In our clinical trial, about 94% of patients rated Sentio’s sound quality as acceptable, natural, or very natural with the vast majority reporting natural or very natural sound.4 (Fig. 1)

Frequency chart

Figure 1: No compensation for placement was applied.5

In contrast, the inherent nonlinearity of the piezoelectric process presents a challenge in maintaining sound fidelity, particularly at higher frequencies. As noted in research on piezoelectric actuator performance, this nonlinearity can lead to harmonic distortion and signal amplitude deviations, particularly when higher frequency signals are processed (ScienceDirect, 2015). For BAHS users, this distortion may result in a degradation of sound quality in the upper frequency range.6

Improved Battery Efficiency

Electromagnetic transducers like those employed in the Sentio System are simpler than their piezoelectric counterparts, as they require fewer electronic components. This reduction in complexity minimizes energy loss, leading to significantly longer battery life for patients.2 Patients benefit from fewer interruptions for battery changes, making the device more convenient and cost-effective over time. Additionally, by simplifying the internal driving circuit, the Sentio transducer minimizes potential failure points, ensuring robust and long-lasting performance.

The Sentio 1 Mini has a battery life of approximately 57 – 60 hours, including up to one hour of streaming.7 This extended performance allows patients to enjoy about three full days of use before needing to replace the battery.

Why the Sentio System Stands Out

The Sentio™ System was developed with a focus on customer needs, both present and future. Featuring the industry’s widest bandwidth, smooth frequency output thanks to our electromagnetic transducer, and proven advanced signal processing, such as the OpenSound Navigator™ and OpenSound Optimizer™, the Sentio System offers an effective and user-friendly solution for patients with mild-to-moderate conductive or mixed hearing losses as well as those with single-sided deafness.

The Sentio Ti Implant is a small implant providing a straightforward, intuitive, and easy installation with flexibility in positioning, enabling more patients to be eligible for surgery. The design choices made for the Sentio Ti Implant also ensure reliability and allow for the use of more powerful sound processors as electronics rapidly advance, all without requiring the patient to undergo additional surgery.

Patients’ benefit from the Sentio device was exemplified in our clinical trial with 97% of participants noting an increase in quality of life, no serious complications post-operatively, no patients reporting feedback 6 months post-activation, and 94%* of patients reporting they were either satisfied or very satisfied with their treatment.7

*Note: The remaining 6% of patients were simply “neutral,” meaning no participants in the clinical trial were dissatisfied with treatment.7

For more information about the Sentio System and how it can benefit your patients, contact your Oticon Medical representative or the Oticon Medical website. You can also access the Sentio System whitepaper by clicking here.

References

  1. Osseointegrated Bone-Conducting Hearing Protheses - StatPearls - NCBI Bookshelf
  2. Data on file. Oticon Medical AB. 2024
  3. Piezoelectric Bone Conduction Hearing Implant: A Case Series of Audiological, Surgical and Patient-Reported Outcomes - PMC
  4. The Sentio™ System – Almost nothing to see, so much to experience [whitepaper]
  5. 275144en Product Information Sentio 1 Mini
  6. Investigation of nonlinearity in piezoelectric transducers - ScienceDirect
  7. Sentio study BC101 summary Doc-00123384
Contact Us

Archives